SUPERSUPERSERVERAS-4021GA-62R+F®USER’S MANUALRevision 1.0a
NotesSUPERSERVER AS-4021GA-62R+F User's Manual
7-10SUPERSERVER AS-4021GA-62R+F User's ManualBlock (Multi-Sector Transfer)Block mode boosts IDE drive performance by increasing the amount of dat
Chapter 7: BIOS7-11IDE Detect Timeout (Sec)Use the +/- keys to adjust and select the time out for detecting ATA/ATAPI de-vices. The default value is 3
7-12SUPERSERVER AS-4021GA-62R+F User's ManualBoots Graphic Adapter PriorityThis setting allows you to select the boot priority for your graphics
Chapter 7: BIOS7-13 Hardware Health Confi gurationCPU Overheat AlarmUse the "+" and "-" keys to set the CPU temperature threshold
7-14SUPERSERVER AS-4021GA-62R+F User's ManualSuspend ModeThis setting selects the ACPI state used for system suspend. Options include S1 (POS), S
Chapter 7: BIOS7-15IP Address SourceThis setting sets the IP address source as either Static or DHCP. Select-ing Static allows you to manually set the
7-16SUPERSERVER AS-4021GA-62R+F User's ManualPCI Express Error LoggingThis setting allows you to Enable or Disable PCI Express Advanced Error Log
Chapter 7: BIOS7-177-6 Exit MenuSelect the Exit tab from AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.Save Changes and Exit When
7-18SUPERSERVER AS-4021GA-62R+F User's ManualNotes
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the
Chapter 1 Introduction1-1 OverviewThe SuperServer AS-4021GA-62R+F is a supercomputing server that is comprised of two main subsystems: the SC747TG-R14
A-2SUPERSERVER AS-4021GA-62R+F User's ManualNotes
Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure Intel South
B-2SUPERSERVER AS-4021GA-62R+F User's ManualB-2 Installing Windows for a Non-RAID SystemInsert Microsoft's Windows XP/Windows 2003 setup CD
C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessorsDual AMD Opteron 2000 series (Socket F type) processorsNote: Please refe
C-2SUPERSERVER AS-4021GA-62R+F User's ManualExpansion SlotsFour (4) PCI-Express x16 Gen 2 slots• Two (2) PCI-Express x4 (in x8) Gen 2 slots• One
C-3Appendix C: System Specifi cationsRegulatory ComplianceElectromagnetic Emissions: FCC Class B, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A
C-4SUPERSERVER AS-4021GA-62R+F User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in li
1-2SUPERSERVER AS-4021GA-62R+F User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer AS-4021GA-62R+F lies the H8DA6+-F, a dual pro
1-3Chapter 1: IntroductionSASAn LSI2008 SAS2 controller is integrated into the chipset to provide two IPASS connectors that can serve up to 8 hot-swap
1-4SUPERSERVER AS-4021GA-62R+F User's ManualSystem PowerEach SC747 chassis model includes a Gold level 1400W High-effi ciency redundant (1+1) powe
1-5Chapter 1: IntroductionFigure 1-1. AMD SR5690/SP5100 Chipset: System Block DiagramNote: This is a general block diagram and may not exactly represe
1-6SUPERSERVER AS-4021GA-62R+F User's Manual1-5 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 9
Chapter 2: Server Installation2-1Chapter 2 System Setup2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer AS-4021GA-62R
2-2SUPERSERVER AS-4021GA-62R+F User's Manual2-3 Setting Up the SystemYou should fi rst open the left side panel (when facing the front of the cha
Chapter 2: Server Installation2-3Check the SAS/SATA disk drives: Depending upon your system's 2. confi guration, your system may have up to eight
Manual Revision 1.0a Release Date: January 29, 2010The information in this User’s Manual has been carefully reviewed and is believed to be accu
2-4SUPERSERVER AS-4021GA-62R+F User's ManualRack PrecautionsEnsure that the leveling jacks on the bottom of the rack are fully extended to • the
Chapter 2: Server Installation2-5Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
2-6SUPERSERVER AS-4021GA-62R+F User's Manual2-5 Installing the Chassis onto a RackThis section provides information on installing the SC747 chas
Chapter 2: Server Installation2-7Removing the Chassis Top CoverLocate the chassis cover lock (blue lever) at the rear of the chassis cover.1. Slide th
2-8SUPERSERVER AS-4021GA-62R+F User's ManualFigure 6-3: Installing the Inner Rack Rails Installing the Chassis Handles and Inner RailsInstalling
Chapter 2: Server Installation2-9Installing the Outer Rails to the RackInstalling the Outer Rails1. Attach the rear bracket to the middle bracket. 2.
2-10SUPERSERVER AS-4021GA-62R+F User's ManualFigure 6-5: Installing the Rack RailsInstalling the Chassis into a RackInstalling the Chassis1. Confi
Chapter 2: Server Installation2-112-6 Tower Mounting InstructionsThe SC747 chassis is shipped with the chassis cover and feet pre-installed. To use
2-12SUPERSERVER AS-4021GA-62R+F User's ManualInstalling Feet on the ChassisInstalling the Chassis FeetPlace the chassis foot in the foot receptac
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the drive carrier
PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an
3-2SUPERSERVER AS-4021GA-62R+F User's Manual3-2 Control Panel ButtonsThere are two push-buttons located on the front of the chassis. These are p
Chapter 3: System Interface3-3NIC2:• Indicates network activity on GLAN2 when fl ashing.Overheat/Fan Fail:• When this LED fl ashes it indicates a fa
3-4SUPERSERVER AS-4021GA-62R+F User's Manual3-4 Drive Carrier LEDsYour chassis uses SAS/SATA drives.SAS/SATA DrivesEach SAS/SATA drive carrier h
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
4-2SUPERSERVER AS-4021GA-62R+F User's ManualThis product may be connected to an IT power system. In all cases, make sure • that the unit is also
Chapter 4: System Safety4-3Remove any jewelry or metal objects from your body, which are excellent metal • conductors that can create short circuits a
4-4SUPERSERVER AS-4021GA-62R+F User's Manual4-4 Operating Precautions!Care must be taken to assure that the chassis cover is in place when the AS
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the H8DA6+-F serverboard
5-2SUPERSERVER AS-4021GA-62R+F User's Manual!UnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge.
Chapter 5: Advanced Serverboard Setup5-3Permanent and Optional StandoffsStandoffs prevent short circuits by securing space between the motherboard and
SUPERSERVER AS-4021GA-62R+F User's Manualivwhen adding or removing processors or main memory and when reconfi guring the serverboard.Chapter 6: Ad
5-4SUPERSERVER AS-4021GA-62R+F User's ManualInstalling the MotherboardInstalling the Motherboard into the ChassisReview the documentation that ca
Chapter 5: Advanced Serverboard Setup5-55-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar
5-6SUPERSERVER AS-4021GA-62R+F User's ManualFigure 5-5. I/O Port Locations and Defi nitionsRear I/O Ports1. PS/2 Keyboard 6. USB 0/1 11. Back Surr
Chapter 5: Advanced Serverboard Setup5-75-5 Installing the Processor and Heatsink!Warning: Avoid placing direct pressure to the top of the processor
5-8SUPERSERVER AS-4021GA-62R+F User's ManualUse your thumb and your index fi nger to 2. hold the CPU. Locate and align pin 1 of the CPU socket wit
Chapter 5: Advanced Serverboard Setup5-9Installing a CPU HeatsinkNote: in single and dual-CPU confi gurations, memory must be installed in the DIMM slo
5-10SUPERSERVER AS-4021GA-62R+F User's ManualRemoving the HeatsinkUse the procedure below to remove a heatsink from a CPU.Warning: We do not reco
Chapter 5: Advanced Serverboard Setup5-11Memory SupportThe H8DA6+-F supports single or dual-channel, DDR2-667/533/400 registered ECC SDRAM. Populating
5-12SUPERSERVER AS-4021GA-62R+F User's ManualGently press down on the DIMM module until it snaps into place in the slot. 3. Repeat for all module
Chapter 5: Advanced Serverboard Setup5-135-6 Adding PCI Add-On CardsThe SuperServer AS-4021GA-62R+F can support four PCI-E Gen. 2.0 x16 cards (in Slo
vPrefaceNotes
5-14SUPERSERVER AS-4021GA-62R+F User's ManualInstall your PCI card or other add-on card into the PCI slot bracket and 5. motherboard. To do this,
Chapter 5: Advanced Serverboard Setup5-15Installing Double-Width Graphics CardsThe SC747 chassis is designed to support up to four double-width, high-
5-16SUPERSERVER AS-4021GA-62R+F User's ManualFigure 5-10: Closing the Graphics Card BracketPlace the tabs of the (part number) graphics card brac
Chapter 5: Advanced Serverboard Setup5-17Figure 5-11. H8DA6+-F Layout(not drawn to scale)5-7 Serverboard DetailsNote: Jumpers not indicated are for te
5-18SUPERSERVER AS-4021GA-62R+F User's ManualH8DA6+/I+(-F) Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (See Section 2-7)JCF1
Chapter 5: Advanced Serverboard Setup5-19LED DescriptionLAN Ports LEDs for the LAN Ethernet portsDedicated IPMI LAN LEDs for the dedicated IPMI LAN Et
5-20SUPERSERVER AS-4021GA-62R+F User's ManualReset ConnectorThe reset connector is located on pins 3 and 4 of JF1 and attaches to the reset switc
Chapter 5: Advanced Serverboard Setup5-21NMI ButtonThe non-maskable interrupt button header is located on pins 19 and 20 of JF1. Refer to the table on
5-22SUPERSERVER AS-4021GA-62R+F User's ManualSerial PortsThe COM1 serial port is located beside the VGA port. Refer to the motherboard layout for
Chapter 5: Advanced Serverboard Setup5-23Overheat LEDConnect an LED to the JOH1 header to pro-vide warning of chassis overheating. See the table on th
viSUPERSERVER AS-4021GA-62R+F User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...
5-24SUPERSERVER AS-4021GA-62R+F User's ManualChassis Intrusion A Chassis Intrusion header is located at JL1. Attach the appropriate cable to info
Chapter 5: Advanced Serverboard Setup5-25IEEE 1394 ConnectionConnectors 1394_1 and 1394_2 provide connectivity for IEEE 1394 (Firewire) de-vices. See
5-26SUPERSERVER AS-4021GA-62R+F User's Manual5-9 Jumper SettingsExplanation of JumpersTo modify the operation of the motherboard, jumpers can be
Chapter 5: Advanced Serverboard Setup5-27VGA Enable/DisableJPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2
5-28SUPERSERVER AS-4021GA-62R+F User's ManualCompact Flash Master/Slave SelectA Compact Flash Master (Primary)/Slave (Secondary) Select Jumper is
Chapter 5: Advanced Serverboard Setup5-295-10 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each
5-30SUPERSERVER AS-4021GA-62R+F User's Manual5-11 Floppy, IDE, SAS and SATA Drive ConnectionsUse the following information to connect the IDE ha
Chapter 5: Advanced Serverboard Setup5-31SATA PortsThere are no jumpers to confi gure the SATA ports, which are designated SATA0 through SATA5. See the
5-32SUPERSERVER AS-4021GA-62R+F User's Manual5-12 Enabling SATA RAIDNow that the hardware is set up, you must install the operating system and t
Chapter 5: Advanced Serverboard Setup5-33Enabling SATA RAID in the BIOSBefore installing the Windows Operating System, you must change some settings i
viiTable of Contents3-3 Control Panel LEDs ...3-23-4 Drive Carr
5-34SUPERSERVER AS-4021GA-62R+F User's ManualFigure 5-12. Adaptec RAID Utility Program ScreenUsing the Adaptec RAID UtilityThe Adaptec® RAID Util
Chapter 5: Advanced Serverboard Setup5-35Figure 5-13. Driver/Tool Installation Display Screen5-13 Installing DriversThe CD that came bundled with the
5-36SUPERSERVER AS-4021GA-62R+F User's ManualSupero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote ma
Chapter 5: Advanced Serverboard Setup5-37Note: Super Doctor III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.com
5-38SUPERSERVER AS-4021GA-62R+F User's ManualNotes
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na
6-2SUPERSERVER AS-4021GA-62R+F User's Manual6-1 Static-Sensitive DevicesElectrostatic Discharge (ESD) can damage electronic com ponents. To preve
Chapter 6: Advanced Chassis Setup6-3The control panel LEDs inform you of system status. See "Chapter 3: System In-terface" for details on th
6-4SUPERSERVER AS-4021GA-62R+F User's ManualRear Fan Release TabFigure 6-4: Rear System Chassis FansFigure 6-3: Mid-System Chassis Fans
Chapter 6: Advanced Chassis Setup6-56-4 Power SupplyThe SC747 chassis has a 1400W (redundant) power supply. This power supply is auto-switching capabl
viiiSUPERSERVER AS-4021GA-62R+F User's ManualBuilding a Driver Diskette ...
6-6SUPERSERVER AS-4021GA-62R+F User's ManualPower Supply Cables Name Qty Connects to: Description20-pin or 24-pin power cable1 Motherboard20-pin
Chapter 6: Advanced Chassis Setup6-76-5 Confi guring the the Storage Module This section covers confi guring the storage module in the SC747 chassis.Sto
6-8SUPERSERVER AS-4021GA-62R+F User's ManualRotating the Storage Module for Rack MountingOpen the chassis cover.1. Locate the storage module and
Chapter 6: Advanced Chassis Setup6-9Figure 6-9: Chassis Storage ModuleTurn the storage module 90 degrees (as illustrated).5. Reinsert the module into
6-10SUPERSERVER AS-4021GA-62R+F User's ManualRemoving a Drive CarrierUse the procedure below to add hard drives to the drive carriers.Adding Hard
Chapter 6: Advanced Chassis Setup6-11Hard DriveHard Drive TrayFigure 6-11: Adding a Hard Drive to the Drive CarrierPlace the hard drive to the hard dr
6-12SUPERSERVER AS-4021GA-62R+F User's ManualAdding Peripheral DrivesYou can add up to three peripheral drives (DVD-ROM, CD-ROM, fl oppy drive, et
Chapter 6: Advanced Chassis Setup6-13Adding Five Hard Drives Using a Supermicro Mobile RackThe SC747 chassis accepts a CSE-M35S (SCSI) or CSE-M35T-1/C
6-14SUPERSERVER AS-4021GA-62R+F User's Manual6-6 Installing Hard Drives in the ChassisChassis hard drives are mounted in drive carriers to simpl
Chapter 6: Advanced Chassis Setup6-15Figure 6-15: Removing a Dummy Drive TrayInsert the hard drive into the chassis. To do this:7. Press the hard driv
Appendix B Installing Windows B-1 Installing Windows for a RAID System ...B-1B-2 Installing
6-16SUPERSERVER AS-4021GA-62R+F User's ManualNotes
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the H8DA6+-F. The AMI ROM BIOS is stored in a F
7-2SUPERSERVER AS-4021GA-62R+F User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory
Chapter 7: BIOS7-37-3 Advanced Settings Menu Boot FeaturesQuick BootIf Enabled, this option will skip certain tests during POST to reduce the time n
7-4SUPERSERVER AS-4021GA-62R+F User's ManualRestore on AC Power LossThis setting allows you to choose how the system will react when power return
Chapter 7: BIOS7-5CPU PrefetchingUse this setting to Enable or Disable CPU prefetching.IO PrefetchingUse this setting to Enable or Disable IO prefetch
7-6SUPERSERVER AS-4021GA-62R+F User's ManualMemory Hole RemappingWhen "Enabled", this feature enables hardware memory remapping around
Chapter 7: BIOS7-7DRAM BG ScrubCorrects memory errors so later reads are correct. Options are Disabled and various times in nanoseconds and microsecon
7-8SUPERSERVER AS-4021GA-62R+F User's Manual Hyper Transport Confi gurationNODE0: PCI-X2 HT LinkLink SpeedThe Hyper Transport link will run at th
Chapter 7: BIOS7-9Legacy USB SupportSelect "Enabled" to enable the support for USB Legacy devices. Disable Legacy support if there are no US
Commenti su questo manuale