SUPERSUPERSERVERAS-4021GA-62R+F®USER’S MANUALRevision 1.0a

Pagina 2

NotesSUPERSERVER AS-4021GA-62R+F User's Manual

Pagina 3 - Manual Organization

7-10SUPERSERVER AS-4021GA-62R+F User's ManualBlock (Multi-Sector Transfer)Block mode boosts IDE drive performance by increasing the amount of dat

Pagina 4

Chapter 7: BIOS7-11IDE Detect Timeout (Sec)Use the +/- keys to adjust and select the time out for detecting ATA/ATAPI de-vices. The default value is 3

Pagina 5

7-12SUPERSERVER AS-4021GA-62R+F User's ManualBoots Graphic Adapter PriorityThis setting allows you to select the boot priority for your graphics

Pagina 6 - Table of Contents

Chapter 7: BIOS7-13 Hardware Health Confi gurationCPU Overheat AlarmUse the "+" and "-" keys to set the CPU temperature threshold

Pagina 7 - Chapter 4 System Safety

7-14SUPERSERVER AS-4021GA-62R+F User's ManualSuspend ModeThis setting selects the ACPI state used for system suspend. Options include S1 (POS), S

Pagina 8 - Chapter 7 BIOS

Chapter 7: BIOS7-15IP Address SourceThis setting sets the IP address source as either Static or DHCP. Select-ing Static allows you to manually set the

Pagina 9

7-16SUPERSERVER AS-4021GA-62R+F User's ManualPCI Express Error LoggingThis setting allows you to Enable or Disable PCI Express Advanced Error Log

Pagina 10

Chapter 7: BIOS7-177-6 Exit MenuSelect the Exit tab from AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.Save Changes and Exit When

Pagina 11 - Introduction

7-18SUPERSERVER AS-4021GA-62R+F User's ManualNotes

Pagina 12 - 1-2 Serverboard Features

A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the

Pagina 13 - 1-3 Server Chassis Features

Chapter 1 Introduction1-1 OverviewThe SuperServer AS-4021GA-62R+F is a supercomputing server that is comprised of two main subsystems: the SC747TG-R14

Pagina 14

A-2SUPERSERVER AS-4021GA-62R+F User's ManualNotes

Pagina 15 - WPCM450-R

Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure Intel South

Pagina 16 - 1-5 Contacting Supermicro

B-2SUPERSERVER AS-4021GA-62R+F User's ManualB-2 Installing Windows for a Non-RAID SystemInsert Microsoft's Windows XP/Windows 2003 setup CD

Pagina 17 - System Setup

C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessorsDual AMD Opteron 2000 series (Socket F type) processorsNote: Please refe

Pagina 18 - 2-3 Setting Up the System

C-2SUPERSERVER AS-4021GA-62R+F User's ManualExpansion SlotsFour (4) PCI-Express x16 Gen 2 slots• Two (2) PCI-Express x4 (in x8) Gen 2 slots• One

Pagina 19 - Choosing a Setup Location

C-3Appendix C: System Specifi cationsRegulatory ComplianceElectromagnetic Emissions: FCC Class B, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A

Pagina 20 - Warnings and Precautions!

C-4SUPERSERVER AS-4021GA-62R+F User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in li

Pagina 21 - Rack Mounting Considerations

1-2SUPERSERVER AS-4021GA-62R+F User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer AS-4021GA-62R+F lies the H8DA6+-F, a dual pro

Pagina 22

1-3Chapter 1: IntroductionSASAn LSI2008 SAS2 controller is integrated into the chipset to provide two IPASS connectors that can serve up to 8 hot-swap

Pagina 23

1-4SUPERSERVER AS-4021GA-62R+F User's ManualSystem PowerEach SC747 chassis model includes a Gold level 1400W High-effi ciency redundant (1+1) powe

Pagina 24

1-5Chapter 1: IntroductionFigure 1-1. AMD SR5690/SP5100 Chipset: System Block DiagramNote: This is a general block diagram and may not exactly represe

Pagina 25

1-6SUPERSERVER AS-4021GA-62R+F User's Manual1-5 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 9

Pagina 26

Chapter 2: Server Installation2-1Chapter 2 System Setup2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer AS-4021GA-62R

Pagina 27 - Installing the Chassis Cover

2-2SUPERSERVER AS-4021GA-62R+F User's Manual2-3 Setting Up the SystemYou should fi rst open the left side panel (when facing the front of the cha

Pagina 28

Chapter 2: Server Installation2-3Check the SAS/SATA disk drives: Depending upon your system's 2. confi guration, your system may have up to eight

Pagina 29 - System Interface

Manual Revision 1.0a Release Date: January 29, 2010The information in this User’s Manual has been carefully reviewed and is believed to be accu

Pagina 30 - 3-3 Control Panel LEDs

2-4SUPERSERVER AS-4021GA-62R+F User's ManualRack PrecautionsEnsure that the leveling jacks on the bottom of the rack are fully extended to • the

Pagina 31

Chapter 2: Server Installation2-5Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Pagina 32 - 3-4 Drive Carrier LEDs

2-6SUPERSERVER AS-4021GA-62R+F User's Manual2-5 Installing the Chassis onto a RackThis section provides information on installing the SC747 chas

Pagina 33 - System Safety

Chapter 2: Server Installation2-7Removing the Chassis Top CoverLocate the chassis cover lock (blue lever) at the rear of the chassis cover.1. Slide th

Pagina 34

2-8SUPERSERVER AS-4021GA-62R+F User's ManualFigure 6-3: Installing the Inner Rack Rails Installing the Chassis Handles and Inner RailsInstalling

Pagina 35 - 4-3 ESD Precautions

Chapter 2: Server Installation2-9Installing the Outer Rails to the RackInstalling the Outer Rails1. Attach the rear bracket to the middle bracket. 2.

Pagina 36 - BATTERY HOLDER

2-10SUPERSERVER AS-4021GA-62R+F User's ManualFigure 6-5: Installing the Rack RailsInstalling the Chassis into a RackInstalling the Chassis1. Confi

Pagina 37 - Advanced Serverboard Setup

Chapter 2: Server Installation2-112-6 Tower Mounting InstructionsThe SC747 chassis is shipped with the chassis cover and feet pre-installed. To use

Pagina 38 - 5-2 Serverboard Installation

2-12SUPERSERVER AS-4021GA-62R+F User's ManualInstalling Feet on the ChassisInstalling the Chassis FeetPlace the chassis foot in the foot receptac

Pagina 39

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the drive carrier

Pagina 40 - Installing the Motherboard

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an

Pagina 41 - 5-3 Connecting Cables

3-2SUPERSERVER AS-4021GA-62R+F User's Manual3-2 Control Panel ButtonsThere are two push-buttons located on the front of the chassis. These are p

Pagina 42 - 5-4 I/O Ports

Chapter 3: System Interface3-3NIC2:• Indicates network activity on GLAN2 when fl ashing.Overheat/Fan Fail:• When this LED fl ashes it indicates a fa

Pagina 43 - Installing a CPU Processor

3-4SUPERSERVER AS-4021GA-62R+F User's Manual3-4 Drive Carrier LEDsYour chassis uses SAS/SATA drives.SAS/SATA DrivesEach SAS/SATA drive carrier h

Pagina 44

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Pagina 45 - Installing a CPU Heatsink

4-2SUPERSERVER AS-4021GA-62R+F User's ManualThis product may be connected to an IT power system. In all cases, make sure • that the unit is also

Pagina 46 - Removing the Heatsink

Chapter 4: System Safety4-3Remove any jewelry or metal objects from your body, which are excellent metal • conductors that can create short circuits a

Pagina 47 - 5-6 Installing Memory

4-4SUPERSERVER AS-4021GA-62R+F User's Manual4-4 Operating Precautions!Care must be taken to assure that the chassis cover is in place when the AS

Pagina 48 - Memory Support

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the H8DA6+-F serverboard

Pagina 49 - 5-6 Adding PCI Add-On Cards

5-2SUPERSERVER AS-4021GA-62R+F User's Manual!UnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge.

Pagina 50

Chapter 5: Advanced Serverboard Setup5-3Permanent and Optional StandoffsStandoffs prevent short circuits by securing space between the motherboard and

Pagina 51

SUPERSERVER AS-4021GA-62R+F User's Manualivwhen adding or removing processors or main memory and when reconfi guring the serverboard.Chapter 6: Ad

Pagina 52

5-4SUPERSERVER AS-4021GA-62R+F User's ManualInstalling the MotherboardInstalling the Motherboard into the ChassisReview the documentation that ca

Pagina 53 - 5-7 Serverboard Details

Chapter 5: Advanced Serverboard Setup5-55-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar

Pagina 54 - H8DA6+/I+(-F) Quick Reference

5-6SUPERSERVER AS-4021GA-62R+F User's ManualFigure 5-5. I/O Port Locations and Defi nitionsRear I/O Ports1. PS/2 Keyboard 6. USB 0/1 11. Back Surr

Pagina 55 - 5 through 8 +12V

Chapter 5: Advanced Serverboard Setup5-75-5 Installing the Processor and Heatsink!Warning: Avoid placing direct pressure to the top of the processor

Pagina 56

5-8SUPERSERVER AS-4021GA-62R+F User's ManualUse your thumb and your index fi nger to 2. hold the CPU. Locate and align pin 1 of the CPU socket wit

Pagina 57

Chapter 5: Advanced Serverboard Setup5-9Installing a CPU HeatsinkNote: in single and dual-CPU confi gurations, memory must be installed in the DIMM slo

Pagina 58

5-10SUPERSERVER AS-4021GA-62R+F User's ManualRemoving the HeatsinkUse the procedure below to remove a heatsink from a CPU.Warning: We do not reco

Pagina 59

Chapter 5: Advanced Serverboard Setup5-11Memory SupportThe H8DA6+-F supports single or dual-channel, DDR2-667/533/400 registered ECC SDRAM. Populating

Pagina 60

5-12SUPERSERVER AS-4021GA-62R+F User's ManualGently press down on the DIMM module until it snaps into place in the slot. 3. Repeat for all module

Pagina 61 - Pin Defi nitions

Chapter 5: Advanced Serverboard Setup5-135-6 Adding PCI Add-On CardsThe SuperServer AS-4021GA-62R+F can support four PCI-E Gen. 2.0 x16 cards (in Slo

Pagina 63

5-14SUPERSERVER AS-4021GA-62R+F User's ManualInstall your PCI card or other add-on card into the PCI slot bracket and 5. motherboard. To do this,

Pagina 64

Chapter 5: Advanced Serverboard Setup5-15Installing Double-Width Graphics CardsThe SC747 chassis is designed to support up to four double-width, high-

Pagina 65 - Off Off Not functioning

5-16SUPERSERVER AS-4021GA-62R+F User's ManualFigure 5-10: Closing the Graphics Card BracketPlace the tabs of the (part number) graphics card brac

Pagina 66

Chapter 5: Advanced Serverboard Setup5-17Figure 5-11. H8DA6+-F Layout(not drawn to scale)5-7 Serverboard DetailsNote: Jumpers not indicated are for te

Pagina 67

5-18SUPERSERVER AS-4021GA-62R+F User's ManualH8DA6+/I+(-F) Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (See Section 2-7)JCF1

Pagina 68 - 5-12 Enabling SATA RAID

Chapter 5: Advanced Serverboard Setup5-19LED DescriptionLAN Ports LEDs for the LAN Ethernet portsDedicated IPMI LAN LEDs for the dedicated IPMI LAN Et

Pagina 69

5-20SUPERSERVER AS-4021GA-62R+F User's ManualReset ConnectorThe reset connector is located on pins 3 and 4 of JF1 and attaches to the reset switc

Pagina 70

Chapter 5: Advanced Serverboard Setup5-21NMI ButtonThe non-maskable interrupt button header is located on pins 19 and 20 of JF1. Refer to the table on

Pagina 71 - 5-13 Installing Drivers

5-22SUPERSERVER AS-4021GA-62R+F User's ManualSerial PortsThe COM1 serial port is located beside the VGA port. Refer to the motherboard layout for

Pagina 72 - Supero Doctor III

Chapter 5: Advanced Serverboard Setup5-23Overheat LEDConnect an LED to the JOH1 header to pro-vide warning of chassis overheating. See the table on th

Pagina 73

viSUPERSERVER AS-4021GA-62R+F User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Pagina 74

5-24SUPERSERVER AS-4021GA-62R+F User's ManualChassis Intrusion A Chassis Intrusion header is located at JL1. Attach the appropriate cable to info

Pagina 75 - Advanced Chassis Setup

Chapter 5: Advanced Serverboard Setup5-25IEEE 1394 ConnectionConnectors 1394_1 and 1394_2 provide connectivity for IEEE 1394 (Firewire) de-vices. See

Pagina 76 - 6-2 Control Panel

5-26SUPERSERVER AS-4021GA-62R+F User's Manual5-9 Jumper SettingsExplanation of JumpersTo modify the operation of the motherboard, jumpers can be

Pagina 77 - 6-3 System Cooling

Chapter 5: Advanced Serverboard Setup5-27VGA Enable/DisableJPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2

Pagina 78 - Release Tab

5-28SUPERSERVER AS-4021GA-62R+F User's ManualCompact Flash Master/Slave SelectA Compact Flash Master (Primary)/Slave (Secondary) Select Jumper is

Pagina 79 - 6-4 Power Supply

Chapter 5: Advanced Serverboard Setup5-295-10 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each

Pagina 80 - Power Supply Connections

5-30SUPERSERVER AS-4021GA-62R+F User's Manual5-11 Floppy, IDE, SAS and SATA Drive ConnectionsUse the following information to connect the IDE ha

Pagina 81 - Tower or Rack Confi guration

Chapter 5: Advanced Serverboard Setup5-31SATA PortsThere are no jumpers to confi gure the SATA ports, which are designated SATA0 through SATA5. See the

Pagina 82 - Rotating the Storage Module

5-32SUPERSERVER AS-4021GA-62R+F User's Manual5-12 Enabling SATA RAIDNow that the hardware is set up, you must install the operating system and t

Pagina 83

Chapter 5: Advanced Serverboard Setup5-33Enabling SATA RAID in the BIOSBefore installing the Windows Operating System, you must change some settings i

Pagina 84 - Removing a Drive Carrier

viiTable of Contents3-3 Control Panel LEDs ...3-23-4 Drive Carr

Pagina 85

5-34SUPERSERVER AS-4021GA-62R+F User's ManualFigure 5-12. Adaptec RAID Utility Program ScreenUsing the Adaptec RAID UtilityThe Adaptec® RAID Util

Pagina 86 - Adding Peripheral Drives

Chapter 5: Advanced Serverboard Setup5-35Figure 5-13. Driver/Tool Installation Display Screen5-13 Installing DriversThe CD that came bundled with the

Pagina 87

5-36SUPERSERVER AS-4021GA-62R+F User's ManualSupero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote ma

Pagina 88

Chapter 5: Advanced Serverboard Setup5-37Note: Super Doctor III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.com

Pagina 89

5-38SUPERSERVER AS-4021GA-62R+F User's ManualNotes

Pagina 90

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na

Pagina 91 - Chapter 7

6-2SUPERSERVER AS-4021GA-62R+F User's Manual6-1 Static-Sensitive DevicesElectrostatic Discharge (ESD) can damage electronic com ponents. To preve

Pagina 92 - 7-2 Main Setup

Chapter 6: Advanced Chassis Setup6-3The control panel LEDs inform you of system status. See "Chapter 3: System In-terface" for details on th

Pagina 93 - 7-3 Advanced Settings Menu

6-4SUPERSERVER AS-4021GA-62R+F User's ManualRear Fan Release TabFigure 6-4: Rear System Chassis FansFigure 6-3: Mid-System Chassis Fans

Pagina 94 - Processor and Clock Options

Chapter 6: Advanced Chassis Setup6-56-4 Power SupplyThe SC747 chassis has a 1400W (redundant) power supply. This power supply is auto-switching capabl

Pagina 95 -  NorthBridge Confi guration

viiiSUPERSERVER AS-4021GA-62R+F User's ManualBuilding a Driver Diskette ...

Pagina 96 -  ECC Confi guration

6-6SUPERSERVER AS-4021GA-62R+F User's ManualPower Supply Cables Name Qty Connects to: Description20-pin or 24-pin power cable1 Motherboard20-pin

Pagina 97 -  DRAM Timing Confi guration

Chapter 6: Advanced Chassis Setup6-76-5 Confi guring the the Storage Module This section covers confi guring the storage module in the SC747 chassis.Sto

Pagina 98

6-8SUPERSERVER AS-4021GA-62R+F User's ManualRotating the Storage Module for Rack MountingOpen the chassis cover.1. Locate the storage module and

Pagina 99 - IDE Confi guration

Chapter 6: Advanced Chassis Setup6-9Figure 6-9: Chassis Storage ModuleTurn the storage module 90 degrees (as illustrated).5. Reinsert the module into

Pagina 100

6-10SUPERSERVER AS-4021GA-62R+F User's ManualRemoving a Drive CarrierUse the procedure below to add hard drives to the drive carriers.Adding Hard

Pagina 101 - PCI/PnP Confi guration

Chapter 6: Advanced Chassis Setup6-11Hard DriveHard Drive TrayFigure 6-11: Adding a Hard Drive to the Drive CarrierPlace the hard drive to the hard dr

Pagina 102 - Remote Access Confi guration

6-12SUPERSERVER AS-4021GA-62R+F User's ManualAdding Peripheral DrivesYou can add up to three peripheral drives (DVD-ROM, CD-ROM, fl oppy drive, et

Pagina 103 - ACPI Confi guration

Chapter 6: Advanced Chassis Setup6-13Adding Five Hard Drives Using a Supermicro Mobile RackThe SC747 chassis accepts a CSE-M35S (SCSI) or CSE-M35T-1/C

Pagina 104 -  Set LAN Confi guration

6-14SUPERSERVER AS-4021GA-62R+F User's Manual6-6 Installing Hard Drives in the ChassisChassis hard drives are mounted in drive carriers to simpl

Pagina 105 - Event Log Confi guration

Chapter 6: Advanced Chassis Setup6-15Figure 6-15: Removing a Dummy Drive TrayInsert the hard drive into the chassis. To do this:7. Press the hard driv

Pagina 106 - 7-5 Boot Menu

Appendix B Installing Windows B-1 Installing Windows for a RAID System ...B-1B-2 Installing

Pagina 107 - 7-6 Exit Menu

6-16SUPERSERVER AS-4021GA-62R+F User's ManualNotes

Pagina 108

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the H8DA6+-F. The AMI ROM BIOS is stored in a F

Pagina 109 - BIOS Error Beep Codes

7-2SUPERSERVER AS-4021GA-62R+F User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory

Pagina 110

Chapter 7: BIOS7-37-3 Advanced Settings Menu Boot FeaturesQuick BootIf Enabled, this option will skip certain tests during POST to reduce the time n

Pagina 111 - Installing Windows

7-4SUPERSERVER AS-4021GA-62R+F User's ManualRestore on AC Power LossThis setting allows you to choose how the system will react when power return

Pagina 112

Chapter 7: BIOS7-5CPU PrefetchingUse this setting to Enable or Disable CPU prefetching.IO PrefetchingUse this setting to Enable or Disable IO prefetch

Pagina 113 - System Specifi cations

7-6SUPERSERVER AS-4021GA-62R+F User's ManualMemory Hole RemappingWhen "Enabled", this feature enables hardware memory remapping around

Pagina 114

Chapter 7: BIOS7-7DRAM BG ScrubCorrects memory errors so later reads are correct. Options are Disabled and various times in nanoseconds and microsecon

Pagina 115 - Regulatory Compliance

7-8SUPERSERVER AS-4021GA-62R+F User's Manual Hyper Transport Confi gurationNODE0: PCI-X2 HT LinkLink SpeedThe Hyper Transport link will run at th

Pagina 116

Chapter 7: BIOS7-9Legacy USB SupportSelect "Enabled" to enable the support for USB Legacy devices. Disable Legacy support if there are no US