Supermicro SuperServer 8025C-3RB, Black Manuale Utente

Navigare online o scaricare Manuale Utente per Server barebone Supermicro SuperServer 8025C-3RB, Black. Supermicro SuperServer 8025C-3RB, Black Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 116
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti

Sommario

Pagina 1 - SUPER

SUPERSUPERSERVER 8025C-3R®USER’S MANUALRevision 1.0a

Pagina 2 - Manual Revision 1.0a

1-2SUPERSERVER 8025C-3R User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 8025C-3R lies the X7QC3, a quad processor serverboar

Pagina 3 - Manual Organization

B-4SUPERSERVER 8025C-3R User's ManualPOST Code Description99h Check for SMART Drive (optional)9Ch Set up Power Management9Dh Initia

Pagina 4

Appendix B: BIOS POST CodesB-5The following are for the boot block in Flash ROMPOST Code DescriptionE0h Initialize the chipsetE1h Initialize

Pagina 5

B-6SUPERSERVER 8025C-3R User's ManualNotes

Pagina 6 - Table of Contents

Appendix C: Intel HostRAID Setup GuidelinesC-1Appendix C HostRAID Setup GuidelinesAfter all the hardware has been installed, you must fi rst confi gure

Pagina 7 - Chapter 4 System Safety

C-2SUPERSERVER 8025C-3R User's ManualThe Intel HostRAID Confi gurationsThe following types of Intel's HostRAID confi gurations are supported:R

Pagina 8

Appendix C: Intel HostRAID Setup GuidelinesC-3Using the Intel ESB2 SATA RAID Utility ProgramCreating, Deleting and Resetting RAID Volumes:After the sy

Pagina 9 - Introduction

C-4SUPERSERVER 8025C-3R User's ManualCreating a RAID 0 VolumeSelect "Create RAID Volume" from the main menu and press the <Enter>

Pagina 10 - 1-2 Serverboard Features

Appendix C: Intel HostRAID Setup GuidelinesC-5Creating a RAID 1 Volume:Select "Create RAID Volume" from the main menu and press the <Ente

Pagina 11 - Other Features

C-6SUPERSERVER 8025C-3R User's ManualCreating a RAID 10 (RAID 1+ RAID 0)Select "Create RAID Volume" from the main menu and press the &l

Pagina 12 - 1-3 Server Chassis Features

Appendix C: Intel HostRAID Setup GuidelinesC-7Creating a RAID 5 Set (Parity)Select "Create RAID Volume" from the main menu and press the <

Pagina 13 - System Block Diagram

1-3Chapter 1: IntroductionOnboard Controllers/PortsOne fl oppy drive controller and an onboard ATA/100 controller are provided to sup-port up to two ID

Pagina 14 - 1-4 Contacting Supermicro

C-8SUPERSERVER 8025C-3R User's ManualDeleting a RAID VolumePress Enter when the Create Volume item is highlighted. A warning message 8. displays.

Pagina 15 - Server Installation

Appendix C: Intel HostRAID Setup GuidelinesC-9From the main menu, select "Reset Disks to Non- RAID" and press <Enter>. 1. The followin

Pagina 16 - Warnings and Precautions!

C-10SUPERSERVER 8025C-3R User's ManualC-2 Installing Windows XP/2000/2003 for RAID SystemsInstalling a New Operating SystemInsert the Microsoft

Pagina 17 - Rack Mounting Considerations

D-1Appendix D: System Specifi cationsAppendix D System Specifi cationsProcessors Four Intel® Xeon® 7300/7200 Series processors. Note: Plea

Pagina 18 - Installing the Outer Rails

D-2SUPERSERVER 8025C-3R User's ManualChassis SC828TQ-R1200LP (2U rackmount) Dimensions (both): (WxHxD) 17.2 x 3.5 x 27.75 in. (473 x 89

Pagina 19

D-3Appendix D: System Specifi cationsCalifornia Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only

Pagina 20

D-4SUPERSERVER 8025C-3R User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life supp

Pagina 21 - 2-6 Preparing to Power On

1-4SUPERSERVER 8025C-3R User's Manual1-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC828TQ-R1200 ser

Pagina 22

1-5Chapter 1: IntroductionFigure 1-1. Intel 7300 Chipset: System Block Diagram Note: This is a general block diagram. See Chapter 5 for details.SOCKET

Pagina 23 - System Interface

1-6SUPERSERVER 8025C-3R User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.

Pagina 24 - 3-3 Control Panel LEDs

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your 8025C-3R up and r

Pagina 25 - 3-4 SAS Drive Carrier LEDs

2-2SUPERSERVER 8025C-3R User's ManualWarnings and Precautions!Choosing a Setup LocationLeave enough clearance in front of the rack to enable you

Pagina 26

Chapter 2: Server Installation2-3Allow the hot plug SAS drives and power supply modules to cool before touch-• ing them.Always keep the rack's fr

Pagina 27 - System Safety

2-4SUPERSERVER 8025C-3R User's Manual2-4 Installing the System into a RackThis section provides information on installing the 8025C-3R into a ra

Pagina 28

Chapter 2: Server Installation2-5Figure 2-1. Installing the Server into a RackInstalling the Server into the RackYou should now have rails attached to

Pagina 29 - 4-3 ESD Precautions

Manual Revision 1.0a Release Date: December 24, 2008The information in this User’s Manual has been carefully reviewed and is believed to be accu

Pagina 30 - BATTERY HOLDER BATTERY HOLDER

2-6SUPERSERVER 8025C-3R User's Manual2-5 Checking the Serverboard SetupAfter you install the 8025C-3R in the rack, you will need to open the top

Pagina 31 - Advanced Serverboard Setup

Chapter 2: Server Installation2-72-6 Preparing to Power OnNext, you should check to make sure the peripheral drives and the SAS drives and SAS backpl

Pagina 32 - 5-2 Serverboard Installation

2-8SUPERSERVER 8025C-3R User's ManualNotes

Pagina 33 - 5-3 Connecting Cables

Chapter 3: System Interface3-1PowerThe main power button is used to apply or remove power from the power supply to the server system. Turning off syst

Pagina 34 - 5-4 I/O Ports

3-2SUPERSERVER 8025C-3R User's Manual21NIC2Indicates network activity on GLAN2 when fl ashing.3-3 Control Panel LEDsThe control panel located on

Pagina 35

Chapter 3: System Interface3-33-4 SAS Drive Carrier LEDsEach SAS drive carrier has two LEDs:Green:• When illuminated, the green LED on the front o

Pagina 36

3-4SUPERSERVER 8025C-3R User's ManualNotes

Pagina 37

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Pagina 38 - 5-6 Installing Memory

SUPERSERVER 8025C-3R User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area around the SuperSer

Pagina 39 - DDR2 FBD DIMM

Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic discharge (ESD) is generated by two objects with different electrical charges coming into

Pagina 40 - 5-8 Serverboard Details

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an

Pagina 41 - X7QC3 Quick Reference

SUPERSERVER 8025C-3R User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the 8025C-3R i

Pagina 42 - 5-9 Connector Defi nitions

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X7QC3 serverboard in

Pagina 43

5-2SUPERSERVER 8025C-3R User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge. When unp

Pagina 44

Chapter 5: Advanced Serverboard Setup5-35-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar

Pagina 45

5-4SUPERSERVER 8025C-3R User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 belo

Pagina 46

Chapter 5: Advanced Serverboard Setup5-55-5 Installing the Processor and Heatsink!Avoid placing direct pressure to the top of the processor package.

Pagina 47

5-6SUPERSERVER 8025C-3R User's ManualCPU InstallationLift the lever on the CPU socket 1. completely as shown in the picture on the right; otherwi

Pagina 48 - 5-10 Jumper Settings

Chapter 5: Advanced Serverboard Setup5-7CEK Heat Sink InstallationDo not apply any thermal grease to the 1. heat sink or the CPU die; the required amo

Pagina 49

5-8SUPERSERVER 8025C-3R User's Manual5-6 Installing MemoryMemory SupportThe X7QC3 supports up to 192 GB fully buffered (FBD) ECC DDR2 667/533 in

Pagina 50

Chapter 5: Advanced Serverboard Setup5-9To Install: Insert module vertically and press down until it snaps into place. Pay attention to the bottom no

Pagina 51

SUPERSERVER 8025C-3R User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X7QC3 serverboard, inclu

Pagina 52 - 5-11 Onboard Indicators

5-10SUPERSERVER 8025C-3R User's ManualFigure 5-5. X7QC3 Layout(not drawn to scale)5-8 Serverboard DetailsPCI Slot4 PCI-X 133MHzJSM1JSM2JVGA1JCOM1

Pagina 53

Chapter 5: Advanced Serverboard Setup5-11X7QC3 Quick ReferenceJumper Description Default SettingJ10/J11 SMB to PCI Slots #3/#4/#5/#6 Both Open (Disabl

Pagina 54

5-12SUPERSERVER 8025C-3R User's ManualReset ConnectorThe reset connector is located on pins 3 and 4 of JF1 and attaches to the reset switch on th

Pagina 55 - Advanced Chassis Setup

Chapter 5: Advanced Serverboard Setup5-13Overheat/Fan Fail LED (OH)Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad-vanced war

Pagina 56 - 6-2 Control Panel

5-14SUPERSERVER 8025C-3R User's ManualFan HeadersThere are nine fan headers on the serverboard, all of which are 4-pin fans. However, pins 1-3 of

Pagina 57 - 6-3 System Fans

Chapter 5: Advanced Serverboard Setup5-15Wake-On-LANThe Wake-On-LAN header is des-ignated JWOL1 on the serverboard. See the table on the right for pi

Pagina 58 - Accessing the Drive Bays

5-16SUPERSERVER 8025C-3R User's ManualSerial PortsTwo serial ports are included on the serverboard. COM1 is a backpanel port and COM2 is a header

Pagina 59 - SAS Drive Installation

Chapter 5: Advanced Serverboard Setup5-17Power SMB (I2C) ConnectorPower SMB (I2 C) connector, located at J13, monitors the status of the power supply,

Pagina 60 - Release button

5-18SUPERSERVER 8025C-3R User's Manual5-10 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used t

Pagina 61 - SAS828TQ

Chapter 5: Advanced Serverboard Setup5-19CMOS ClearJBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper cons

Pagina 63

5-20SUPERSERVER 8025C-3R User's ManualCompact Flash Master/Slave SelectA Compact Flash Master (Primary)/Slave (Secondary) Select Jumper is locate

Pagina 64

Chapter 5: Advanced Serverboard Setup5-21SAS/SATA Enable/DisableJumper Settings (JPS1)Jumper Setting Defi nition Pins 1-2 SAS/SATA EnabledPins

Pagina 65 - Chapter 7

5-22SUPERSERVER 8025C-3R User's Manual5-11 Onboard IndicatorsGLAN1/2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each

Pagina 66 - 7-2 Main Setup

Chapter 5: Advanced Serverboard Setup5-235-12 Floppy, IDE, and SAS PortsUse the following information to connect the IDE hard disk drive cables.A red

Pagina 67 - 7-3 Advanced Settings

5-24SUPERSERVER 8025C-3R User's ManualSATA PortsThere are no jumpers to confi g-ure the onboard SATA connec-tors. See the table on the right for p

Pagina 68 - IDE Confi guration Submenu

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na

Pagina 69 - PIO Mode

6-2SUPERSERVER 8025C-3R User's ManualFigure 6-1. Front and Rear Chassis Views6-2 Control PanelThe control panel (located on the front of the chas

Pagina 70

Chapter 6: Advanced Chassis Setup6-36-3 System FansSix heavy-duty redundant hot-swap fans provide the cooling for the SuperServer 8025C-3R. The fans a

Pagina 71 - PCI/PnP Confi guration

6-4SUPERSERVER 8025C-3R User's ManualFigure 6-2. Removing System Cooling Fans6-4 Drive Bay Installation/RemovalAccessing the Drive BaysSAS Drive

Pagina 72 - Advanced Chipset Settings

Chapter 6: Advanced Chassis Setup6-5SAS Drive InstallationThe SAS drives are mounted in drive carriers to simplify their installation and removal from

Pagina 73

viSUPERSERVER 8025C-3R User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Pagina 74

6-6SUPERSERVER 8025C-3R User's ManualFigure 6-4. Removing a SAS Drive Carrier!Important: All of the SAS drive carriers must remain in the drive b

Pagina 75

Chapter 6: Advanced Chassis Setup6-7SAS Drive BackplaneThe SAS drives plug into a backplane that provides power, drive ID and bus termi-nation. A RAID

Pagina 76 - USB Confi guration

6-8SUPERSERVER 8025C-3R User's Manual6-5 Power SupplyThe SuperServer 8025C-3R has a 1200 watt redundant power supply consisting of two power modu

Pagina 77 - APCI Confi guration

Chapter 6: Advanced Chassis Setup6-9Figure 6-6. Removing a Power Supply Module

Pagina 78 - APM Confi guration

6-10SUPERSERVER 8025C-3R User's ManualNotes

Pagina 79

Chapter 7: BIOS7-1Chapter 7 BIOS7-1 IntroductionThis chapter describes the AMIBIOS Setup Utility for the X7QC3. The AMI ROM BIOS is stored in a Flash

Pagina 80 - Hardware Health Confi guration

7-2SUPERSERVER 8025C-3R User's Manual7-2 Main SetupWhen you fi rst enter the AMI BIOS Setup Utility, you will enter the Main setup screen. You can

Pagina 81 - XMPS Confi guration

Chapter 7: BIOS7-37-3 Advanced SettingsThe Advanced Settings screen and submenus are listed below:WarningWhen you fi rst enter the Advanced Setup scree

Pagina 82 - Remote Access Confi guration

7-4SUPERSERVER 8025C-3R User's ManualIntel Virtualization Technology (Available when supported by the OS and the CPU.)Select Enabled to use the f

Pagina 83 - Trusted Computing

Chapter 7: BIOS7-5TypeThis feature allows the user to select the type of device connected to the system. The options are Not Installed, Auto, CDROM, a

Pagina 84 - 7-4 Boot Confi guration

viiTable of ContentsLocking Tabs ...2-4Installing the Serve

Pagina 85 - Hard Disk Drive

7-6SUPERSERVER 8025C-3R User's ManualDMA ModeSelect Auto to allow the BIOS to automatically detect the DMA mode. Use this value if the IDE disk d

Pagina 86 - CD/DVD Drives

Chapter 7: BIOS7-7XFloppy Confi guration This option allows the user to confi gure the settings for the Floppy Drives installed in the system.Floppy A/

Pagina 87 - 7-5 Security Settings

7-8SUPERSERVER 8025C-3R User's ManualOffboard PCI/ISA IDE CardThis option allows the user to assign a PCI slot number to an off-board PCI/ISA IDE

Pagina 88 - 7-6 Exit Options

Chapter 7: BIOS7-9XNorthBridge Confi gurationThis feature allows the user to confi gure the NorthBridge Chipset settings.Crystal Beach/DMAThis feature u

Pagina 89 - Load Fail-Safe Defaults

7-10SUPERSERVER 8025C-3R User's ManualFBD Thermal Throttle ModeSelect Enabled to use the feature of closed-loop thermal throttling on a fully buf

Pagina 90

Chapter 7: BIOS7-11USB2 ControllerSelect Enabled to activate the onboard USB2 controller. The options are Enabled and Disabled.SLP_S4# Minimum Asserti

Pagina 91 - BIOS POST Messages

7-12SUPERSERVER 8025C-3R User's ManualXEvent Log Confi gurationHighlight this item and press <Enter> to view the contents of the event log.V

Pagina 92

Chapter 7: BIOS7-13XUSB Mass Storage Device Confi gurationThis feature allows the user to confi gure the USB Mass Storage Device set-tings.USB Mass Stor

Pagina 93

7-14SUPERSERVER 8025C-3R User's ManualXChipset ACPI Confi gurationHigh Precision Event TimeSelect Enabled to activate the High Precision Event Tim

Pagina 94

Chapter 7: BIOS7-15Advanced Resume Event ControlResume On RingIf set to Enabled, the system will be "awakened" when the modem receives an in

Pagina 95

viiiSUPERSERVER 8025C-3R User's Manual5-9 Connector Defi nitions ...

Pagina 96

7-16SUPERSERVER 8025C-3R User's ManualXHardware Health Confi gurationThis feature allows the AMI BIOS to automatically display the status of the f

Pagina 97 - BIOS POST Codes

Chapter 7: BIOS7-17XMPS Confi guration This section allows the user to confi gure the multiprocessors table.MPS RevisionThis feature allows the user to

Pagina 98

7-18SUPERSERVER 8025C-3R User's ManualXSMBIOS Confi gurationSMBIOS SMI SupportSelect Enabled to enable the function of SMBIOS SMI Wrapper support

Pagina 99

Chapter 7: BIOS7-19Terminal TypeThis feature allows the user to select the target terminal type for Console Redirection.The options are ANSI, VT100, a

Pagina 100 - POST Code Description

7-20SUPERSERVER 8025C-3R User's Manual7-4 Boot Confi gurationThis feature allows the user to confi gure the following items:XBoot SettingsQuick B

Pagina 101

Chapter 7: BIOS7-21Parity CheckingThis option allows the user to enable or disable SB IDCHK# and PCI SERR# Parity Checking. The options are Enabled an

Pagina 102

7-22SUPERSERVER 8025C-3R User's ManualXRemovable DrivesThis feature allows the user to specify the boot sequence from available Remov-able Drives

Pagina 103 - HostRAID Setup Guidelines

Chapter 7: BIOS7-23Change Supervisor PasswordSelect this option and press <Enter> to access the Submenu, and then type in the password. Change U

Pagina 104 - The Intel Matrix Storage

7-24SUPERSERVER 8025C-3R User's Manual7-6 Exit OptionsSelect the Exit tab from the AMIBIOS Setup Utility screen to enter the Exit BIOS Setup scre

Pagina 105

Chapter 7: BIOS7-25Load Fail-Safe DefaultsTo set this feature, select Load Fail-Safe Defaults from the Exit menu and press <Enter>. The Fail-Saf

Pagina 106

Chapter 1 Introduction1-1 OverviewThe SuperServer 8025C-3R is a high-end server that is comprised of two main subsystems: the SC828TQ-R1200 2U server

Pagina 107

7-26SUPERSERVER 8025C-3R User's ManualNotes

Pagina 108

A-1Appendix A: BIOS POST MessagesAppendix A BIOS POST MessagesDuring the Power-On Self-Test (POST), the BIOS will check for problems. If a prob-lem is

Pagina 109

A-2SUPERSERVER 8025C-3R User's ManualSystem CMOS checksum bad - Default confi guration usedSystem CMOS has been corrupted or modifi ed incorrectly,

Pagina 110

A-3Appendix A: BIOS POST MessagesEISA CMOS not writeableServerBIOS2 test error: Cannot write to EISA CMOS.DMA Test FailedServerBIOS2 test error: Canno

Pagina 111

A-4SUPERSERVER 8025C-3R User's Manualnnnn kB Extended RAM PassedWhere nnnn is the amount of RAM in kilobytes successfully tested.nnnn Cache SRAM

Pagina 112

A-5Appendix A: BIOS POST MessagesPS/2 Mouse:PS/2 mouse identifi ed.Run the I2O Confi guration UtilityOne or more unclaimed block storage devices have th

Pagina 113 - System Specifi cations

A-6SUPERSERVER 8025C-3R User's ManualNotes

Pagina 114

Appendix B: BIOS POST CodesB-1Appendix B BIOS POST CodesThis section lists the POST (Power On Self Test) codes for the Phoenix BIOS. POST codes are d

Pagina 115

B-2SUPERSERVER 8025C-3R User's ManualPOST Code Description14h Initialize keyboard controller16h 1-2-2-3 BIOS ROM checksum17h Initia

Pagina 116

Appendix B: BIOS POST CodesB-3POST Code Description5Bh Disable CPU cache5Ch Test RAM between 512 and 640 kB60h Test extended memory62h

Commenti su questo manuale

Nessun commento