Supermicro AOC-USASLP-L8I Manuale Utente Pagina 20

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 104
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 19
AOC-USASLP-L8i Add-on Card User’s Manual
4-2
The number of physical drives in a specific array determines the possible RAID levels
that you can implement with the array. See Section 2-3: "RAID Minimum Drive
Requirements" on page 2-3 for further details.
Starting the MegaRAID BIOS CU
Follow these steps to start the MegaRAID BIOS CU:
1. During boot-up, wait for the following message to appear on the screen:
Press Ctrl-M to run LSI Software RAID Setup Utility
2. When you see this message, hold down the C
TRL key while pressing the M-KEY.
The RAID CONFIGURATION UTILITY MANAGEMENT MENU screen appears, as shown in
Figure 4-1.
Using Easy Configuration
When you select the Easy Configuration Option, the CU creates one or more arrays
from the available physical drives and configures each array as a single virtual drive. If
virtual drives have already been configured, the CU does not change their configuration.
Figure 4-1. RAID Configuration Utility Management Menu Screen
Vedere la pagina 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 103 104

Commenti su questo manuale

Nessun commento