SUPERSERVER8047R-TRF+8047R-7RFT+® SUPERUSER'S MANUALRevision 1.0a
NotesxSUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL
7-14SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALSATA Confi gurationWhen this submenu is selected, the AMI BIOS automatically detects the presence o
Chapter 7: BIOS7-15RAID ModeThe following items are displayed when RAID Mode is selected:Port 0~5 Hot PlugSelect Enabled to enable hot-plug support fo
7-16SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALASPM SupportThis feature allows the user to set the Active State Power Management (ASPM) level for
Chapter 7: BIOS7-17Super IO Confi gurationSuper IO Chip: This item displays the Super IO chip used in the motherboard.Serial Port 1 Confi gurationSeri
7-18SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALDevice ModeUse this feature to select the desired mode for a serial port specifi ed. The options ar
Chapter 7: BIOS7-19Data BitsUse this feature to set the data transmission size for Console Redirection. The options are 7 Bits and 8 Bits. ParityA par
7-20SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALPutty KeyPadThis feature selects Function Keys and KeyPad settings for Putty, which is a terminal e
Chapter 7: BIOS7-21Flow ControlThis feature allows the user to set the fl ow control for Console Redirection to prevent data loss caused by buffer over
7-22SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALTrusted Computing (Available when a TPM device is detected by the BIOS)Confi gurationTPM SupportSel
Chapter 7: BIOS7-23CPU: TXT (Trusted Execution Technology) FeatureChipset: TXT (Trusted Execution Technology) FeatureIntel TXT (LT-SX) Confi gurationTh
Chapter 1 Introduction1-1 OverviewThe SuperServer 8047R-TRF+/7RFT+ is a high-end server comprised of two main subsystems: the SC748TQ-R1K43BP 4U serve
7-24SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL7-4 Event LogsUse this feature to confi gure Event Log settings.Change SMBIOS Event Log SettingsThi
Chapter 7: BIOS7-25SMBIOS Event Log Standard SettingsLog System Boot EventSelect Enabled to log system boot events. The options are Disabled and Enabl
7-26SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL7-5 IPMIUse this feature to confi gure Intelligent Platform Management Interface (IPMI) settings.
Chapter 7: BIOS7-27BMC Network Confi gurationLAN Channel 1/LAN Channel 2:This feature allows the user to confi gure the settings for LAN1/LAN 2 Ports.U
7-28SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL7-6 BootThis submenu allows the user to confi gure the following boot settings for the system.Boot
Chapter 7: BIOS7-297-8 Save & ExitThis submenu allows the user to confi gure the Save and Exit settings for the system.Discard Changes and Exit Se
7-30SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALSave as User DefaultsSelect this feature and press <Enter> to save the current settings as th
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the
A-2SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALNotes
B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessorsQuad Intel E5-4600 Series series (Socket R-LGA 2011 type) processorsNote
1-2SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL• If you have any questions, please contact our support team at [email protected] Serverboar
B-2SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALExpansion SlotsFour PCI low-profi le expansion card slots are available in the rear of the chassis fo
B-3Appendix B: System Specifi cationsRegulatory ComplianceElectromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A
B-4SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL(continued from front)The products sold by Supermicro are not intended for and will not be used in l
Chapter 1: Introduction1-3SAS (8047R-7RFT+ Server Only)A LSI® 2208 SAS controller is integrated into the serverboard to provide an eight port SAS (Ser
1-4SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALHard Drive SubsystemThe SC748TQ-R1K43BP chassis was designed to support fi ve 3.5" hot-swap SATA
Chapter 1: Introduction1-5Cooling SystemThe SC748TQ-R1K43BP chassis has an innovative cooling design that includes three 8-cm and three 9.2-cm hot-plu
1-6SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 1-1. Intel C602 Chipset: System Block DiagramNote: This is a general block diagram. Please se
Chapter 1: Introduction1-71-5 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408
1-8SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALNotes
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 8047R-
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu
2-2SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL• This product is for installation only in a Restricted Access Location (dedicated equipment rooms,
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
2-4SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL2-5 Installing the System into a RackThis section provides information on installing the SC748 chas
Chapter 2: Server Installation2-5Figure 2-1: Remove the Chassis Cover and FeetChassis FeetChassis CoverChassis Cover Lock
2-6SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 2-2: Identifying the Inner Rails and Chassis HandlesChassis HandleInner RailsChassis HandleSc
Chapter 2: Server Installation2-7Figure 2-4: Installing the Inner Rack Rails 2. Align the chassis handle with the front of the chassis and secure wit
2-8SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALInstalling the Outer Rails to the Rack (Figure 2-5)1. Attach the front and rear short brackets to t
Chapter 2: Server Installation2-9Installing the Chassis into a Rack1. Confi rm that chassis includes the inner rails and the outer rails. 2. Line chas
2-10SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 6-7: Installing the Chassis into a Rack3. Slide the chassis rails into the rack rails, keep
Chapter 2: Server Installation2-112-6 Tower Confi guration InstructionsThe SC748 chassis is shipped with the chassis cover and feet pre-installed. To u
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta
2-12SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL2-7 Checking the Serverboard SetupAfter you setup the 8047R-TRF+/7RFT+ (in the rack or tower confi
Chapter 2: Server Installation2-13Figure 5-1: Removing the Chassis CoverRemove Screws14131213Checking the Components and Setup1. You may have one or
2-14SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL2-8 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives and the
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the drive carrier
SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL3-23-3 Control Panel LEDsThe control panel located on the front of the chassis has several LEDs. These
Chapter 3: System Interface3-312Universal Information LEDWhen this LED blinks red quickly, it indicates a fan failure and when blinking red slowly a p
SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL3-43-4 Drive Carrier LEDsEach drive carrier has two LEDs:SATA Drives• Green: When illuminated, the gre
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL4-2• Serverboard Battery: CAUTION - There is a danger of explosion if the onboard CR2032 battery is ins
Chapter 4: System Safety4-34-3 ESD Precautions!Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into
SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALivChapter 6: Advanced Chassis SetupRefer to Chapter 6 for detailed information on the SC748TQ-R1K43BP s
SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the Su
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X9QRi-F+/X9QR7-TF+ s
5-2SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL5-2 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables t
Chapter 5: Advanced Serverboard Setup5-35-3 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 below
5-4SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL5-4 Installing the Processor and HeatsinkCaution! Avoid placing direct pressure to the top of the p
Chapter 5: Advanced Serverboard Setup5-52. Press the second load lever labeled 'Close 1st' to release the load plate that covers the CPU so
5-6SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL5. Use your thumb and index fi nger to hold the CPU on its edges. Align the CPU keys, which are semi
Chapter 5: Advanced Serverboard Setup5-77. With the CPU inside the socket, inspect the four corners of the CPU to make sure that the CPU is properly
5-8SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALInstalling a Passive CPU Heatsink1. Do not apply any thermal grease to the heatsink or the CPU die
Chapter 5: Advanced Serverboard Setup5-9OPEN 1stLoosen screws in sequence as shown.Screw#2MotherboardScrew#1Screw#3Removing the HeatsinkCaution: We do
NotesPrefacev
5-10SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL5-5 Installing MemoryCaution! Exercise extreme care when installing or removing DIMM modules to pre
Chapter 5: Advanced Serverboard Setup5-11Processor & Memory Module Population Confi gurationFor memory to work properly, follow the tables below fo
5-12SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALPopulating Memory ModulesIntel E5-4600 Series Processor UDIMM Memory SupportRanks Per DIMM & Da
Chapter 5: Advanced Serverboard Setup5-135-6 Adding PCI-E Add-On CardsThe SC748TQ-R1K43BP chassis can accommodate all the card slots of the X9QRi-F+/
5-14SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 5-4. X9QRi-F+/X9QR7-TF+ Layout5-7 Serverboard DetailsJPW1JPI2C1JP5JP4USB6/7JLPC1JD1JF1JPW5JP
Chapter 5: Advanced Serverboard Setup5-15X9QRi-F+/X9QR7-TF+ Quick Reference Jumper Description Default SettingJBT1 Clear CMOS See Section 5-9JPB1 BMC
5-16SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALReset ButtonPins 3 and 4 of JF1 attaches to the reset button on the computer chassis. See the table
Chapter 5: Advanced Serverboard Setup5-17Overheat/Fan/Pwr Fail/UID LEDConnect an LED to pins 7 and 8 of JF1 to use the Overheat/Fan Fail/Power Fail/UI
5-18SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFan HeadersThere are eight fan headers on the serverboard, all of which are 4-pin fans. However, pi
Chapter 5: Advanced Serverboard Setup5-19Serial PortsCOM1 is located on the rear I/O panel. COM2, located close to PCI-E Slot2, provides front access
viTable of ContentsChapter 1 Introduction1-1 Overview ...
5-20SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALT-SGPIO 1/2 HeadersTwo SGPIO (Serial-Link General Purpose Input/Output) headers are located on the
Chapter 5: Advanced Serverboard Setup5-21Universal Serial Bus (USB)Four Universal Serial Bus ports (USB0/1, USB2/3) are located on the I/O back panel.
5-22SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL5-10 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can b
Chapter 5: Advanced Serverboard Setup5-23VGA Enable/DisableJPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2
5-24SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL5-11 Onboard IndicatorsIPMI Dedicated LAN LEDsIn addition to LAN 1/LAN 2, an IPMI Dedicated LAN is
Chapter 5: Advanced Serverboard Setup5-255-12 SAS/SATA PortsSATA PortsThere are no jumpers to confi gure the onboard SATA ports. These ports are suppo
5-26SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL5-13 Installing SoftwareAfter the hardware has been installed, you should fi rst install the operati
Chapter 5: Advanced Serverboard Setup5-27Supero Doctor IIIThe SuperDoctor® III program is a Web base management tool that supports remote management c
5-28SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALNote: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform maintenan
viiReliable Ground ... 2-32-5 Installing the System into a Rack
6-2SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 6-1. Front and Rear Chassis Views6-2 Control PanelThe control panel (located on the front of
Chapter 6: Advanced Chassis Setup6-36-3 Confi guring the Storage ModuleThis section covers confi guring the storage module for the SC748 chassis. The st
6-4SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 6-4: Chassis Storage ModuleRotating the Storage Module for Rack Mounting1. Open the chassis
Chapter 6: Advanced Chassis Setup6-5Storage Module Release LeverStorage ModuleFigure 6-5: Remove the Storage ModuleAdding Drives to the Storage Module
6-6SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALInstalling Hard Drives into the Drive Tray1. Open the chassis cover.2. Locate the drive tray you w
Chapter 6: Advanced Chassis Setup6-7Figure 6-7: Add a Hard Drive to the Drive TrayHard DriveHard Drive TrayAdding Peripheral Drives (DVD-ROM, CD-ROM,
6-8SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALHard Drive RailsHard Drive TrayFigure 6-8: Add Hard Drive Rails to the DVD-ROM DriveAdding Five Hard
Chapter 6: Advanced Chassis Setup6-94. Install all six storage module rails onto the mobile rack. Each rail requires two screws. Make sure the arrow
6-10SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL6-4 Installing Hard DrivesThe drives are mounted in drive carriers to simplify their installation
Chapter 6: Advanced Chassis Setup6-115. Secure the hard drive to the tray using four screws (Figure 6-13).Figure 6-12: Removing the Dummy Drive TrayD
viii5-5 Installing Memory ... 5-10Memory Support ...
6-12SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALAdd-on Card/Expansion Slot SetupAfter motherboard installation, install add-on cards to the chassis
Chapter 6: Advanced Chassis Setup6-134. Remove the screw holding the bracket in place and pull the bracket from the chassis (Figure 6-15).5. Install
6-14SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUAL6-5 Installing the Air ShroudAir shrouds concentrate airfl ow to maximize fan effi ciency. The SC748
Chapter 6: Advanced Chassis Setup6-156-6 System FansSix heavy duty fans provide cooling for the chassis. Three fans are located in the front of the ch
6-16SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 6-19: Rear Chassis FansReplacing a Rear Chassis FanRear Fan Replacement Procedure (Figure 6-
Chapter 6: Advanced Chassis Setup6-176-7 Power Supply Depending on your chassis model, the SC748 Chassis has a 1400 Watt (redundant) power supply. Thi
6-18SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALFigure 6-20: Removing a Power SupplyPress the Release Button1213Pull the Drive OutUsing the Handle
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the SuperServer 8047R-TRF+/7RFT+. The 16 MB SPI
7-2SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALSystem TimeThis item displays the system time in HH:MM:SS format (e.g. 15:32:52).Supermicro X9QR7-TF
Chapter 7: BIOS7-3Interrupt 19 CaptureInterrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Immediate,
7-6 Boot ... 7-287-7 Security ...
7-4SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALCPU Confi gurationThis submenu displays the information of the CPU as detected by the BIOS. It also
Chapter 7: BIOS7-5RTID (Record Types IDs)This feature displays the total number of Record Type IDs for local and remote pools. The options are Optimal
7-6SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALDCU Streamer Prefetcher (Available when supported by the CPU)Select Enabled to support Data Cache Un
Chapter 7: BIOS7-7P-STATE CoordinationThis feature selects the type of coordination for the P-State of the processor. P-State is a processor operatio
7-8SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALLong Duration Power LimitThis item displays the power limit (in watts) set by the user during which
Chapter 7: BIOS7-9Data Direct I/OSelect Enabled to enable Intel I/OAT (I/O Acceleration Technology), which signifi cantly reduces CPU overhead by lever
7-10SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALCPU 1 PCIe Slot 3 Link SpeedSelect GEN1 to enable PCI-Exp Generation 1 support for Slot 3. Select G
Chapter 7: BIOS7-11DIMM Confi gurationThis section displays the following DIMM information.Current Memory ModeThis item displays the current memory mo
7-12SUPERSERVER 8047R-TRF+/7RFT+ USER'S MANUALDDR SpeedUse this feature to force a DDR3 memory module to run at a frequency other than what is sp
Chapter 7: BIOS7-13Thermal ThrottlingThrottling improves reliability and reduces power consumption in the processor via automatic voltage control duri